شماره ركورد :
1289305
عنوان مقاله :
شبيه سازي عددي مبدل حرارتي سه لوله اي با مواد تغييرفاز دهنده و اثر تغييرشكل لوله با كارايي آنها
عنوان به زبان ديگر :
Numerical Simulation of the Effect of Tube Shape on the Triplex-Tube Heat Exchanger and Exergy Efficiency using Phase Change Material
پديد آورندگان :
عصاري، محمد رضا داﻧﺸﮕﺎه ﺻﻨﻌﺘﯽ ﺟﻨﺪي ﺷﺎﭘﻮر - داﻧﺸﮑﺪه ﻣﻬﻨﺪﺳﯽ ﻣﮑﺎﻧﯿﮏ , بصيرت تبريزي، حسن داﻧﺸﮕﺎه ﺻﻨﻌﺘﯽ اﻣﯿﺮﮐﺒﯿﺮ - داﻧﺸﮑﺪه ﻣﻬﻨﺪﺳﯽ ﻣﮑﺎﻧﯿﮏ , پرور، حسن مرﮐﺰ ﭘﮋوﻫﺸﯽ ﺟﻨﺪي ﺷﺎﭘﻮر , زكي زاده، رضا داﻧﺸﮕﺎه ﺻﻨﻌﺘﯽ ﺟﻨﺪي ﺷﺎﭘﻮر - داﻧﺸﮑﺪه ﻣﻬﻨﺪﺳﯽ ﻣﮑﺎﻧﯿﮏ
تعداد صفحه :
21
از صفحه :
160
از صفحه (ادامه) :
0
تا صفحه :
180
تا صفحه(ادامه) :
0
كليدواژه :
مبدل حرارتي , ماده‌تغييرفازدهنده , ضريب كارايي , تحليل انرژي , تحليل اگزرژي , لوله‌سينوسي , لوله دندانه‌اي
چكيده فارسي :
در اﯾﻦ ﭘﮋوﻫﺶ از آب ﺑﻪ ﻋﻨﻮان ﺳﯿﺎل ﺟﺎري در ﻟﻮﻟﻪﻫﺎي داﺧﻠﯽ و ﺧﺎرﺟﯽ، و ﻟﻮﻟﻪ ﻣﯿﺎﻧﯽ ﺑﻪ ﻋﻨﻮان ﻣﺎده ﺗﻐﯿﯿﺮﻓﺎزدﻫﻨﺪه در ﯾﮏ ﻣﺒﺪل ﺳﻪ ﻟﻮﻟﻪاي اﺳﺘﻔﺎده ﺷﺪهاﺳﺖ. ﺑﺎ اﺳﺘﻔﺎده از روش آﻧﺘﺎﻟﭙﯽ ﻣﺘﺨﻠﺨﻞ ﻣﻘﺎﯾﺴﻪاي ﺑﯿﻦ ﻟﻮﻟﻪ ﻣﺴﺘﻘﯿﻢ، دﻧﺪاﻧﻪاي و ﺳﯿﻨﻮﺳﯽ ﺑﻪﻋﻨﻮان ﻟﻮﻟﻪ دروﻧﯽ اﻧﺠﺎم ﺷﺪهاﺳﺖ. ﻫﻤﭽﻨﯿﻦ ﺑﺮرﺳﯽ ﺿﺮﯾﺐ ﮐﺎراﯾﯽ، ﺑﺎزده اﮔﺰرژي و اﻧﺮژي و ﺗﺎﺛﯿﺮ ﺗﻐﯿﯿﺮ دﺑﯽ ﺟﺮﻣﯽ ﺑﺮ ذوب ﻣﺎده ﺗﻐﯿﯿﺮﻓﺎزدﻫﻨﺪه ﻣﻮرد ﻣﻄﺎﻟﻌﻪ ﻗﺮارﮔﺮﻓﺖ. ﻧﺘﺎﯾﺞ ﻧﺸﺎن داد ﮐﻪ ﺑﻬﺘﺮﯾﻦ زﻣﺎن ذوب را در ﻣﺒﺪل ﺳﻪ ﻟﻮﻟﻪاي، ﻟﻮﻟﻪ ﺳﯿﻨﻮﺳﯽ و ﻫﻤﭽﻨﯿﻦ ﺑﺮاي ﺿﺮﯾﺐ ﮐﺎراﯾﯽ، ﺑﺎزده اﻧﺮژي و اﮔﺰرژي ﻣﺒﺪلﻫﺎي ﺳﯿﻨﻮﺳﯽ و دﻧﺪاﻧﻪاي ﺑﻬﺘﺮ از ﻟﻮﻟﻪ ﻣﺴﺘﻘﯿﻢ ﻣﯽﺑﺎﺷﺪ. ﺑﺎ اﻓﺰاﯾﺶ دﺑﯽ ﺑﺮاي ﺟﺮﯾﺎن آرام و ﻣﻐﺸﻮش زﻣﺎن ذوب ﺑﻪ ﺗﺮﺗﯿﺐ ﺣﺪاﮐﺜﺮ ﺗﺎ 2/6 و 13/5 درﺻﺪ ﮐﺎﻫﺶ ﻣﯽﯾﺎﺑﺪ.
چكيده لاتين :
Different inner tube shapes of the triplex tube heat exchanger with phase change material has been investigated numerically. Water is used as the working fluid in the inner and outer tubes, and the middle tube is filled with RT35 as a phase change material (PCM). The PCM effectiveness among the inner tube shapes such as straight, indented, and sinusoidal in a triplex tube heat exchanger were studied. Energy and exergy efficiencies, and the effect of mass flow rate on the melting process of PCM have been sought. Enthalpy-porosity method has been applied for the simulation. Results demonstrate that the best melting time in triplex tube heat exchanger has been observed in the sinusoidal tube, and by increasing the number of pitches, the melting time decreases. In addition, sinusoidal and indented tube heat exchangers effectiveness are better than straight tube. Melting time is reduced by maximum of 2.6% by increasing the flow rate of a laminar flow from 0.006 kg/s to 0.012 kg/s. Moreover, the melting time is reduced by a maximum of 13.5% for the turbulent condition with flow rate of 0.024 kg/s. In the analysis of energy and exergy, the indented tube shows higher and preferable efficiency in comparison to the sinusoidal and straight type.
سال انتشار :
1401
عنوان نشريه :
مهندسي مكانيك ايران
فايل PDF :
8692232
لينک به اين مدرک :
بازگشت