همبستگي كيفيت هواي محيطهاي بسته و هواي بيرون در مناطقي با آلودگي هواي زياد - تهران 1382
عنوان به زبان ديگر :
Correlation of Indoor Air quality and outdoor Air quality at places with high Air pollution in Tehran -1382
پديد آورندگان :
شفيع پور، مجيد نويسنده , , مقدم ، روزيتا مترجم ,
اطلاعات موجودي :
فصلنامه سال 1384 شماره 24
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
16
از صفحه :
1
تا صفحه :
16
كليدواژه :
كيفيت هوا , همبستگي , محيط هاي بسته , Air quality , آلودگي هوا , indoor , محيط زيست , Correlation
چكيده لاتين :
Nowadays the majority of people spend 80% to 90% of their time indoors and hence different cur pollutants target them. This study aims at establishing a Correlation between the air pollution concentrations rrf outdoors and indoors air quality. The main indoor air pollutants, namely CO and PMI0 have been identified as. real problems of Tehran s indoor air quality. Topographically, Tehran is a howl shaped city with lacks rain, contains weather inversion during 70% of the year. uses older models and used vehicle in the streets, and has no wind for half the year. This research covers different types of locations, for measuring indoor and outdoor air quality such as, residential(R) and office (0) environments. For field studies, 5 stations were selected within a 500meter radius. The locations selected are: Nejatollahi(O), Pardison(O), Faiemi(O), Gholhak(R) and with different terrains. Simultaneous measurements of air pollution concentrations were made between 8:00 to /6:00 in both indoor and outdoor conditions. The study shows that there are direct significant correlations between indoor air quality and nearby outdoor air conditions. The ratio of indoor air pollutants concentration to outdoor air pollutants concentration is defined as p. GRIMM and CO measuring instruments were used For sampling and particle deliberateness. The measurement results for different locations indicate: 1. Stations and areas totally affected by open space show extreme influence of indoor air quality from nearby outdoor by signifting p 80%./Ur PM 10and 45% for- CO. Fariation of p.shows, p co has more tendencies to a straight line than p PM10 so pco, is between 37% to 68% and under similar circumstances, p PM10 is 69% to 92%. 2. Air condition is very important in buildingsʹ to push particles• and CO out and prevent pollution from coming in. 3. Finally, the result of total measurement of the five stations as follows: About 70% of locations heavily depend on CO, 10% depend a little on co, and I8% show no dependency on CO. 27% of tested areas sere highly affected by PM10, 36% with low dependency and 27% with no dependency on PM10-.
سال انتشار :
1384
عنوان نشريه :
علوم و تكنولوژي محيط زيست
عنوان نشريه :
علوم و تكنولوژي محيط زيست
اطلاعات موجودي :
فصلنامه با شماره پیاپی 24 سال 1384
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت