عنوان مقاله :
مقايسه روشهاي غيرفعال سازي حرارتي و مهار با اوره در اندازه گيري ايزو آنزيمهاي استخواني و كبدي آلكالين فسفاتاز
عنوان به زبان ديگر :
COMPARISON OF HEAT INACTIVATION AND UREA INHIBITION METHODS FOR DETERMINATION OF BONE AND LIVER ALKALINE PHOSPHATASE ISOENZYMES
پديد آورندگان :
محجوب ف سليمان ، نويسنده , , ژيلا مسرور رود سري ، مترجم ,
اطلاعات موجودي :
فصلنامه سال 1384
رتبه نشريه :
فاقد درجه علمي
كليدواژه :
غيرفعال سازي حرارتي , اوره , ايزوآنزيم استخواني , ايزوآنزيم كبدي , آلكالين فسفاتاز , ALP , alkaline phosphatase , Liver isoenzyme , Urea inhibition method , Heat inactivation method. , Bone isoenzyme
چكيده لاتين :
BACKGROUND AND OBJECTIVE: The alkaline phosphatase (ALP) enzyme has several isoenzymes in different tissues. Bone and liver isoenzymes are abundant and prominent. The purpose of this study was to develope and compare the heat inactivation and urea inhibition methods in measurement of bone and liver alkaline phosphatase isoenzymes. METHODS: Determination of total ALP activity of liver and bone isoenzymes was carried out for several times per day and during consecutive days. Precision and reliability of these methods were confirmed after 10 times repeat of all experiments on two normal, one liver choiestase and one bone pagerʹs serum samples. Then it was set up heat inactivation and urea methods in biochemistry laboratory of Babel University of Medical Sciences. In addition to, on SO normal serum samples of adolescents, determination of total ALP activity by AACC- IFCC standard method and bone and liver isoenzymes was carried out by heat inactivation and urea inhibition methods.
FINDINGS: The results of bone and liver isoenzymes activity by heat inactivation and urea inhibition methods were about in mean±ISD intervals. CVs of heat inactivation method for liver and bone isoenzymes were 3.17 and 3.73 and CVs of urea inhibition method for liver and bone isoenzymes were 3.33 and 4.46, respectively. Comparison of urea inhibition method with heat inactivation method, demonstrated a good coefficient of correlation for liver (r = 0.964) and bone (r = 0.961) isoenzymes.
CONCLUSION: The heat inactivation and urea inhibition methods are cheap and had acceptable precision and reliability and good accuracy. These methods are useful for determination of ALP isoenzymes especially when bone and liver are involved.
عنوان نشريه :
مجله دانشگاه علوم پزشكي بابل
عنوان نشريه :
مجله دانشگاه علوم پزشكي بابل
اطلاعات موجودي :
فصلنامه با شماره پیاپی سال 1384
كلمات كليدي :
#تست#آزمون###امتحان