شماره ركورد :
181203
عنوان مقاله :
كاربرد پروب الكتريكي يك و دوسوزني براي اندازه گيري در جريانهاي مخلوط آب و هوا
عنوان به زبان ديگر :
Application of One and Double Needle Electrical Probe for Measurement in Air-Water Flows
اطلاعات موجودي :
دو ماهنامه سال 1383 شماره 88
رتبه نشريه :
فاقد درجه علمي
تعداد صفحه :
12
از صفحه :
735
تا صفحه :
746
كليدواژه :
جريان مخلوط آب و هوا , پروب الكتريكي , پروب سوزني , One and Double Needle Electrical Probe , مهندسي عمران , Air-Water Flows
چكيده لاتين :
In the present paper application of a one-needle and a double-needle electrical probe with developed specifications is introduced for measurement in air-water flows. The new one-needle probe has the capability of measuring air concentration and bubble count with very high sampling frequency. Another advantage of this probe is real time measurement and on-line presentation of results. More than 30 sets of tests were carried out in air-water flows to calibrate the probe and to determine the circuit threshold level. To measure the velocity of air-water mixture a doubld-needle electrical probe is employed. The specifications of the double-needle probe are similar to the one-needle probe with addition of one needle to make it capable of measuring flow velocity. To ensure the performance of the double-needle probe, its measurements were compared with a pitot tube. This comparison showed that the maximum difference in measurements was less than 4%.
سال انتشار :
1383
عنوان نشريه :
نشريه دانشكده فني دانشگاه تهران
عنوان نشريه :
نشريه دانشكده فني دانشگاه تهران
اطلاعات موجودي :
دوماهنامه با شماره پیاپی 88 سال 1383
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت