عنوان مقاله :
اعتبار نوار تك مرحله اي گنادوتروپينهاي كوريوني انساني بتا جهت تشخيص پارگي پيش از موعد پرده هاي جنيني
عنوان به زبان ديگر :
Diagnostic power of one-step beta human chorionic gonadotropin (BHCG) test strips in detecting premature rupture of membranes
پديد آورندگان :
كريمان ، نورالسادات نويسنده دانشكده پرستاري و مامايي-دانشگاه علوم پزشكي و خدمات بهداشتي و درماني شهيد بهشتي kariman, nourosaddat , علوي مجد، حميد نويسنده دانشكده پيراپزشكي Alavimajd, H. , جعفري، الهام نويسنده دانشكده پرستاري و مامايي-دانشگاه علوم پزشكي و خدمات بهداشتي درماني زنجان , , اميرمقدمي، حميدرضا نويسنده بيمارستان آموزشي و درماني وليعصر-دانشگاه علوم پزشكي زنجان , , احمدي دولابي، محبوبه نويسنده دانشكده پرستاري و مامايي-دانشگاه علوم پزشكي و خدمات بهداشتي درماني شهيد بهشتي ,
اطلاعات موجودي :
فصلنامه سال 1388 شماره 65
كليدواژه :
پارگي پيش از موعد پرده هاي جنيني , ترشحات سرويكوواژينال , گنادوتروپينهاي كوريوني انساني بتا , قدرت تشخيصي
چكيده لاتين :
Background and aim
With respect to the prevalence and complications of premature rupture of chorionic membranes (PROM) and the importance of correct and on-time detection of the disorder with false positive or negative results, accurate as well as noninvasive diagnostic procedures are always needed.This case-control study was conducted to identify the diagnostic power of qualitative evaluation of beta human chorionic gonadotropins (BHCG) in cervicovaginal discharge with 1- step test strips (25 IU/ml) for detecting PROM in women referring to Vali-e-Asr Hospital at Zanjan city in 2007. Materials and methods
86 singletons between 14 and 41 weeks of gestation were selected. Data collection tools included a form for demographic information as well as gestational history and an observation checklist for speculum examination and tests of Fern, nitrazine and qualitative strip for BHCG. Of women with amniotic fluid leakage, subjects were examined in 2 43-person groups including those with definite PROM (direct observation with speculum [+], Fern test [+] and nitrazine test [+]) in case group and those with intact membranes (direct observation with speculum [-], Fern test [-] and nitrazine test [-]) in control group. Subjects were matched in terms of gestational weeks in the two groups.
Cervicovaginal discharge samples were taken by rinsing posterior fornix with 5ml saline and
aspiration of fluid. BHCGs were then tested by 1-step gestational strips.
Findings
It was found that sensitivity, specificity, positive as well as negative predictive values and
accuracy of the strips were 97.7%, 88.4%, 89.4%, 97.5% and 93%.
Conclusion
It seems that the diagnostic power of qualitative evaluation of BHCGs in cervicovaginal discharge to detect PROM is acceptable