عنوان مقاله :
مقايسه ميزان آزادسازي يون نيكل و محل ايجاد خوردگي در چند نوع براكت استينلس استيل رايج در بازار ايران
عنوان به زبان ديگر :
Comparison of Nickel Ion Release and Corrosion Sites among Commonly Used Stainless Steel
Brackets in Iran
پديد آورندگان :
جهان بين، آرزو نويسنده گروه ارتودنتيكس-دانشكده دندانپزشكي و مركز تحقيقات دندانپزشكي-دانشكده دندانپزشكي مشهد Jahanbin, Arezoo , شهابي، مصطفي نويسنده گروه ارتودنتيكس-دانشكده دندانپزشكي و مركز تحقيقات دندانپزشكي -دانشگاه علوم پزشكي مشهد Shahabi, Mostafa , مخبر، نيما نويسنده گروه ارتودنتيكس-دانشكده دندانپزشكي و مركز تحقيقات دندانپزشكي -دانشگاه علوم پزشكي مشهد Mokhber, Nima , توكليان اردكاني، الهام نويسنده TavakkolianArdakani, Elharn
اطلاعات موجودي :
فصلنامه سال 1388 شماره 68
كليدواژه :
نيكل , nickel , ايران , Corrosion , براكت , Bracket , خوردگي , دندانپزشكي
چكيده لاتين :
Introduction: One of the characteristics of brackets is resistance to corrosion. Corrosion could disturb dental movement through increasing. the friction between arch wire and slot. It could also cause dental discoloration. The aim of this study was to compare corrosion rate as well as corrosion site of five commonly used brackets in Iran.
Materials & Methods: In this in vitro experimental study, 80 lower central stainless steel brackets (18- slot) from different
companies (Mira. Dentaurum, Forte, loli and 3M) were selected. At first, the brackets were mounted in Rapid impression material and the photographs were taken from six different views for assessing slots. bases, and wings using stereomicroscope device with X50 magnification. Then, each 8 brackets were put into a capped glass containing artificial saliva with PH=7.2 and they were incubated in 37± 1°c temperature. The amount of released Nickel ion was measured by Atomic absorption technique after 6 weeks and for each bracket, photographs were taken again from previous views. Statistical analysis was done using Chi-square. Cochrane and Kruskal-Wallis and McNimar tests.
Results: The minimum Nickel ion release belonged to 3M brackets (0.86±0. I PPB) and the maximum release was for Forte
brackets (17 .49±0.0 I PPB). Furthermore. corrosion was seen more in bracket bases (mesh surfaces) and it was less observed in their faces.
Conclusion: The order of the Nickel ion release was: 3M
عنوان نشريه :
مجله دانشكده دندانپزشكي مشهد
عنوان نشريه :
مجله دانشكده دندانپزشكي مشهد
اطلاعات موجودي :
فصلنامه با شماره پیاپی 68 سال 1388
كلمات كليدي :
#تست#آزمون###امتحان