شماره ركورد
415552
عنوان مقاله
استخراج پارامترهاي بهينه در ايجاد هيپرمي غير فعال براي افزايش توانايي اتساع پذيري شريان بازويي
عنوان به زبان ديگر
Extraction of Optimum Parameters of Inducing Reactive Hyperaemia for Increasing Distensibility of
Brachial Artery
پديد آورندگان
رفعتي، مهرآور نويسنده دانشكده علوم پزشكي- دانشگاه تربيت مدرس , , مختاري ديزجي، منيژه نويسنده گروه فيزيك پزشكي- دانشگاه تربيت مدرس تهران Mokhrari-Dizaji, M. , صابري، هژير نويسنده مركز تصويربرداري بيمارستان امام خميني- دانشگاه علوم پزشكي تهران , , چگيني، حسين نويسنده مركز تصويربرداري بيمارستان امام خميني- دانشگاه علوم پزشكي تهران ,
اطلاعات موجودي
فصلنامه سال 1387
رتبه نشريه
علمي پژوهشي
تعداد صفحه
13
از صفحه
112
تا صفحه
124
كليدواژه
اولتراسونوگرافي , هيپرمي غير فعال , پارامترهاي بيومكانيكي , شريان بازويي , Ultrasonography , Biomechanics , University of medical sciences
چكيده لاتين
Introduction: Nowadays, noninvasive evaluation of dilatation changes of endothelium region under
hyperaemia has attracted researchersʹ notice. But optimum conditions for inducing hyperaemia and proper
mechanical parameters based on obstruction stress, obstruction time and time of ultrasonic. survey after
obstruction release were not reported. This study was designed to extract optimum biomechanical
parameters for inducing hyperaemia in brachial artery.
Method: First, brachial artery of healthy men were forced under 0, 50, 100, 150, 200, 250 mmHg for five
minutes, and 60 seconds after obstruction release ultrasonic assessment was performed and according to
maximum distensibility of brachial artery, optimum obstruction was extracted. Then brachial artery of
healthy men were forced under optimum obstraction for I, 2, 3, 4, 5 minutes and optimum obstruction time
was extracted. For extracting the optimum time ofultrasonic assessment, brachial artery of healthy men were
forced underoptimum obstruction pressure and time and then ultrasonic assessment was done in 30, 45. 60.
75, 90 seconds after obstruction release. For extracting diameter changes of artery. maximum systolic
velocity, minimum diastolic velocity. and also radial strain and distensibility, multi frames of B-mode and
Doppler images were recorded on personal computer. According to ANOVA test, optimum parameters of
inducing reactive hyperaemia for increasing distensibility of brachial artery were extracted.
Results: Hyperaemia under 150mmllg obstruction, for a duration of 4 minutesand 45 and 65 secondsafter
releasing are the best conditions for ultrasonic assessments.
Conclusion: The application of optimum reactive hyperaemia protocol can provide a more accurate
noninvasive evaluation ofartriesʹ biomeehanical parameters.
سال انتشار
1387
عنوان نشريه
مجله دانشگاه علوم پزشكي كرمان
عنوان نشريه
مجله دانشگاه علوم پزشكي كرمان
اطلاعات موجودي
فصلنامه با شماره پیاپی سال 1387
كلمات كليدي
#تست#آزمون###امتحان
لينک به اين مدرک