عنوان مقاله :
گزارش يك مورد خارج كردن كاتتر شكسته شده از بطن راست قلب
عنوان به زبان ديگر :
RETRIEVAL OF BROKEN CATHETER FROM
RIGHT HEART VENTRICULAR
پديد آورندگان :
اسكندري، رامين نويسنده دانشگاه علوم پزشكي اروميه Eskandari, R , سيدمحمدزاده، ميرحسين نويسنده دانشگاه علوم پزشكي اروميه SEID MOHAMMAD ZADEH, M. , رستم زاده ، علي رضا نويسنده دانشگاه علوم پزشكي اروميه Rostamzadeh, A.R. , خادم وطن ، كمال نويسنده دانشگاه علوم پزشكي اروميه Khademvatan, K , خياطي شال، ابراهيم نويسنده دانشگاه علوم پزشكي اروميه KHAIATI SHAL, E.
اطلاعات موجودي :
فصلنامه سال 1388
كليدواژه :
كاتتر شكسته شده , روش اسنير , روش هاي مداخله اي , كاتتر NIH , Interventional , Snare technique , Fractured catheter
چكيده لاتين :
With the rapid advancement and broad range of applications of invasive cardiovascular procedures,
the rate of complications from such techniques including intravascular foreign bodies are on the rise.
These complications can lead to various other adverse outcomes, such as thrombus formation,
migration of the foreign body to other vital organs, cardiac arrhythmia and infections. Removal of
such objects is performed by either surgery or intervcntional techniques, with the latter being
preferred.
The patient was a 60-year old woman presented with dyspnea, nausea and hemorrhage from a
permanent jugular catheter that had been used for hemodialysis, because her AV fistula has been malfunctioning.
Her past medical history included chronic renal failure.
As part of the work up, a blood culture was performed that turned positive for coagulase positive
staphylococcus aureus. This led to decision to remove the jugular catheter. During the procedure, the
catheter was broken and a long segment of it was embolized through the superior vena cava to the
heart. Patient is transferred to the angiography unit. The two ends of a 0-014" guide wire arc passed
through the two orifices of an NIH catheter. By passing the two ends of the guide wire at the tip of the
NIH catheter an adjustable loop is formed that can trap the foreign body. Using a pigtail catheter, the
broken piece is pulled into the IVe. The NIH catheter was then used to successfully pull the object
out of the femoral vein.
A literature survey revealed that the incidence of catheter fracture is about 0% to 2.1%. Emboilization
of fractured catheter maybe fatal. The chosen technique to remove fractured particle is a catheter based
method (interventional).
A commercially available device, called snare, can be used to retrieve the fractured catheter. Since the
conventional snare was not available, a similar device was built using NIH catheter and guide wire. In
cases with high risk of complication in snaring of fractured catheter, the loose particle should be
repositioned by a pigtail and then retrieved by snare.
عنوان نشريه :
مجله پزشكي اروميه
عنوان نشريه :
مجله پزشكي اروميه
اطلاعات موجودي :
فصلنامه با شماره پیاپی سال 1388
كلمات كليدي :
#تست#آزمون###امتحان