عنوان مقاله :
اثر Manual glide path بر ميزان نقص يا شكستگي فايل هاي چرخشي Mtwo در درمان ريشه دندان
عنوان به زبان ديگر :
Role of manual glide path on better use of rotary Mtwo instruments
پديد آورندگان :
ضرابي، محمدحسن نويسنده دانشكده و مركز تحقيقات دندانپزشكي-دانشگاه علوم پزشكي مشهد Zarrabi, Mohammadhasan , جاويدي، مريم نويسنده دانشكده دندانپزشكي - دانشگاه علوم پزشكي مشهد Javidi, Maryam , وطن پور، مهدي نويسنده گروه آموزشياندودنتيكس-دانشكده دندانپزشكي - دانشگاه آزاد اسلامي تهران Vatanpour, Mehdi , اسماعيلي، حبيب الله نويسنده گروه آموزشي پزشكي اجتماعي-دانشكده علوم پزشكي و خدمات بهداشتي درماني-دانشگاه علوم پزشكي مشهد-بيمارستان قايم Esmaeeli, H
اطلاعات موجودي :
فصلنامه سال 1387 شماره 68
كليدواژه :
Manual glide path , فايل هاي چرخشي نيكل تيتانيوم , Manual glide path (تماس ملايم فايل دستي با ديواره كانال) , ريشه دندان , نقص , شكستگي
چكيده لاتين :
Background & Aim: Increased fracture rate of different rotary NiTi files has influenced the prognosis of root canal therapies. Torsion fatigue is one of the most important factors influencing the fracture rate of these rotary instruments due to increased contact area between file and canal walls. The manual glide path is one of the recommended methods to decrease this problem. The purpose of this study was to investigate the influence of manual glide path on fracture or separation rate of NiTi rotary instruments.
Materials & Methods: This experimental study was conducted using 160 root canals of human molar teeth with mild curvature of 15 to 35 degrees. Samples were divided into two groups. In group one manual glide path was carried out with k-type SS#10-20. The final preparation was performed with Mtwo files using crown down technique. The root canals in group two were instrumented with Mtwo files without prior application of manual glide path procedure. Data were collected and analyzed using ANOVA, Mann-Whitney and Mantel-Cox tests.
Results: Based on the results of this study, the three variables under investigation in both groups showed significant differences with each other when the defect (P=0.039) fracture or defect (P=0.005), and number of prepared canals (P=0.042) were compared. Survival analysis of Kaplan-Meier demonstrated that, the safety probability after preparation of 10 canals were 81.5% and 53.7% in group one and two respectively. The Mantel–Cox test showed significant difference between the two groups in terms of file working time (P=0.002).
Conclusion: Based on these results, the fracture and defect can considerably be decreased when using SS hand files for preparation of apical third, before using NiTi rotary instruments. Key words: Manual glide path - Defect - Fracture - NiTi rotary files.
Corresponding Author: Dr. Zarrabi MH., Professor, Endodontics Department and member of Dental Research Center, Faculty of Dentistry, Mashhad University of Medical Sciences. Mashhad, Iran.