ارباب زاده، فرحناز نويسنده گروه آموزشي ترميمي-دانشكده دندانپزشكي-دانشگاه علوم پزشكي اصفهان Arbabzadeh, Farahnaz , رضوي، محمد نويسنده گروه آموزشي آسيب شناسي دهان فك و صورت-دانشكده دندانپزشكي- دانشگاه علوم پزشكي و خدمات بهداشتي درماني اصفهان Razavi, S.Mohamma , صميمي، پوران نويسنده گروه آموزشي ترميمي-دانشكده دندانپزشكي-دانشگاه علوم پزشكي اصفهان Samimi, Poran , چهاركامه، مريم نويسنده Chaharkameh, Maryam
اطلاعات موجودي :
فصلنامه سال 1387 شماره 68
كليدواژه :
زوليران , ارزيابي هيستوپاتولوژيك , زيست سازگاري , زونالين
چكيده لاتين :
Background & Aim: Biocompatibility of dental materials can help in their proper handling and usage in dental clinics. Zonalin is a foreign brand, reinforced Zinc Oxide Eugenol in two forms of liquid and powder. Zoliran is a similar compound produced in Iran. The purpose of this in-vivo study was to compare the biocompatibility of the two cements by using an animal model.
Materials and Methods: This experimental study was conducted using twelve 3-4 month-old female rats weighing 150-200 grams. The two cements (Zonalin and Zoliran) were implanted into subcutaneous tissues of each rat. Zonalin was implanted in two sites on the left side of the body and Zoliran in two sites on the right side. The area in the center of the four sites was used as the control site, which was opened and sutured without any implantation. Biopsies were taken after 3, 15, 30 and 60 days intervals (3 rats were used at a time). The tissues were fixed in buffered formalin, sectioned and stained with Hematoxylin and Eosin according to standard methods.
Results: No considerable differences in the inflammatory responses were observed between the two materials at all time intervals. Similarly, no significant tissue response was noted for each material over time. The inflammatory response at test locations was always higher than the control sites at all time intervals.
Conclusion: Although mild inflammation was observed, both materials under investigation appeared to be biocompatible and well tolerated.