شماره ركورد :
429830
عنوان مقاله :
تعيين ضرايب تصحيح تصاوير در تكنيك پانوراميك با استفاده از فانتوم فك پايين
عنوان به زبان ديگر :
Correction factors determination for panoramic radiography using a phantom of mandible.
پديد آورندگان :
شيرازي، عليرضا نويسنده دانشگاه علوم پزشكي تهران,دانشكده پزشكي; Shirazi, A , طلايي پور، احمدرضا نويسنده دانشگاه علوم پزشكي تهران,دانشكده دندانپزشكي; Talaiepoor, AR , نوروزپور، ياسر نويسنده ; Noroozpoor, Y , باشي زاده فخار، حوريه نويسنده دانشگاه علوم پزشكي تهران,دانشكده دندانپزشكي; Bashizade Fakhar, H , قاسم زاده، علي نويسنده بيمارستان شريعتي,; Ghasemzade, A , شاكري، ناصر نويسنده دانشگاه علوم پزشكي تهران,مركز تحقيقات علوم و تكنولوژي در پزشكي; ,
اطلاعات موجودي :
فصلنامه سال 1387 شماره 56
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
7
از صفحه :
182
تا صفحه :
188
كليدواژه :
راديوگرافي , پانوراميك , ضريب تصحيح , بدشكلي , بزرگنمايي
چكيده لاتين :
Background and Aim: Image distortion is one of the major problems in panoramic radiography. Horizontal and vertical correction factors could be determined for more efficient clinical applications. The purpose of this study was to determine horizontal and vertical correction factors in panoramic radiography. Materials and Methods: In this test evaluation study in which an asymetric mandibular phantom was constructed by plexiglass and aluminium as soft and hard tissue equivalents. The right half was slightly shorter than the left half. Steel markers were installed to make vertical and horizontal measurments possible. The length of the markers as well as the intermarker distances were measured by Mitutoyo digital micrometer which was accurate within ±0.05mm. The phantom was then positioned in PM 2002 cc proline (Planmeca, Finland) panoramic machine and panoramic images were obtained. 8 times for each half of the phan. The same length and inter marker distances were measured on digitized panoramic images by Cygnus software, which was accurate whitin ±0.01 mm. Magnification and correction factors were determined for the vertical and horizontal dimensions in each region of pantomograms. Results: The mean vertical correction factor was 0.77±0.02 (range: 0.75-0.80) in the right and 0.77±0.05 (range: 0.75-0.85) in the left half jaw. The mean horizontal correction factor was calculated as 0.98±0.15 (range: 0.76-1.18) in the right and 1.02±0.14 (range: 0.90-1.25) in the left half jaw. Conclusion: Dissimilarity of vertical and horizontal correction factors among left and right half jaws and also in different regions of a half jaw is relatively considerable. However, a constant correction factor, specialy in horizontal aspect, could not be applicable. Comparing with horizontal correction factors the vertical correction factors showed less variations between different regions as well as different samples.
سال انتشار :
1387
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
اطلاعات موجودي :
فصلنامه با شماره پیاپی 56 سال 1387
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت