عنوان مقاله :
Application of Bivariate Calibration Method and Derivative Spectrophotometry to Simultaneous Quantitative Resolution of Ethinylestradiol and
عنوان به زبان ديگر :
Application of Bivariate Calibration Method and Derivative Spectrophotometry to Simultaneous Quantitative Resolution of Ethinylestradiol and
پديد آورندگان :
سهرابي، محمود رضا نويسنده Department of Chemistry, Islamic Azad University, North Tehran Branch,Tehran, Iran. Sohrabi, Mahmood Reza , محمدپور، خديجه نويسنده Department of Chemistry, Islamic Azad University, North Tehran Branch,Tehran, Iran. Mohammadpour, Khadijeh
اطلاعات موجودي :
فصلنامه سال 1388 شماره 10
كليدواژه :
Bivariate calibration , Ethinylestradiol , Derivative spectrophotometry , Levonorgestrel , Quantitative
چكيده فارسي :
روش كاربرد روش كاليبراسيون دو متغيره براي آناليز كمي همزمان اتينيل استراديول(ETE) و لونورجسترول(LEV) در فرمولاسيون دارويي و نتيجه ها با نتايج به دست آمده از روش اسپكتروفتومتري مشتقي مرتبه اول مقايسه شد. در روش كاليبراسيون دو متغيره يك جفت بهينه طول موج جهت تجزيه ي كمي انتخاب شد. اندازه گيري هاي طول موج هاي 240/4 نانو متر براي ETE و 257/8 نانومتر براي LEV صورت پذيرفت. روش هاي مورد نظر با تجزيه كمي محلول هاي سنتزي با نسبت متفاوت از هر دو آناليت معتبر سازي شدند و مقدار هاي بالاي بازيافت با دقت خوب به دست آمد. ميانگين بازيافت با روش كاليبراسيون دو متغيره %103/4 و %102/9 و با روش اسپكتروفتومتري مشتقي %102/4 و %98/2 به ترتيب جهت اتينيل استراديول و لونورجسترول به دست آمد. همچنين مقايسه نتايج به دست آمده از تجزيه كمي همزمان در فرمولاسيون دارويي با اين دو روش با سطح اطمينان %95 تفاوت معناداري با مقدار واقعي نشان نمي دهد.
چكيده لاتين :
The bivariate calibration method was applied to the quantitative resolution
of ethinylestradiol (ETE) and levonorgestrel (LEV) in pharmaceutical
formulations and the results were compared with those given by first derivative
spectrophotometry. In the bivariate spectrophotometric method, an optimum pair of
wavelengths was chosen for the determination. The determination was performed at
240.4 nm for ETE and at 257.8 nm for LEV. In the first-derivative spectrophotometry
determination of ETE and LEV was realized by measurements of amplitudes of derivative
spectra corresponding to zero-crossing points of LEV and ETE at 241 and 248.4 nm,
respectively. The proposed procedures were validated by using various synthetic
mixtures with high percentage of recovery and good precision. Mean recovery values
were found 103.4% and 102.9 % for bivariate calibration method and 102.4% and 98.2
% for derivative spectrophotometry, respectively, for determination of ETE and LEV
in synthetic mixtures. Also good agreement between the results obtained using the two
procedures was found, which agreed also with the product label.
عنوان نشريه :
پژوهش هاي كاربردي در شيمي
عنوان نشريه :
پژوهش هاي كاربردي در شيمي
اطلاعات موجودي :
فصلنامه با شماره پیاپی 10 سال 1388
كلمات كليدي :
#تست#آزمون###امتحان