عنوان مقاله :
بررسي دقت ابعادي نوعي هيدروكلوييد برگشتناپذير پس از ضد عفوني با محلول ازن در آب
عنوان فرعي :
Dimensional accuracy of irreversible hydrocolloid impressions disinfected with ozonated water
پديد آورندگان :
نجاتي دانش ، فرحناز نويسنده Professor, Biomaterial Dental Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Ira Nejati Danesh, Farahnaz , صوابي، اميد نويسنده Professor, Torabinejad Dental Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Ira Savabi, Omid , عسگري ، سيدنويد نويسنده Postgraduate Student, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. Asgari, Sayed Navid , شفيعي ، صوفيا نويسنده Postgraduate Student, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. Shafie, Sofia
اطلاعات موجودي :
فصلنامه سال 1391 شماره 0
كليدواژه :
ازن , ضد عفوني , غوطهوري , كنترل عفونت , مواد ضد عفوني كننده , مواد قالبگيري دندانپزشكي
چكيده فارسي :
چكيده
مقدمه: ضد عفوني قالبهاي تهيه شده از دهان بيمار در پيشگيري از انتقال عفونت از اهميت خاصي برخوردار است. هدف از اين پژوهش، بررسي ثبات ابعادي نوعي ماده قالبگيري هيدروكلوييد برگشتناپذير پس از ضد عفوني با محلول ازن در آب به روش غوطهوري و اسپري بود.
مواد و روشها: در اين تحقيق تجربي- آزمايشگاهي، 50 قالب هيدروكلوييد برگشتناپذير از يك مدل آكريلي فك بالا شامل 4 عدد آنالوگ اباتمنت Straumann تهيه و به 5 گروه 10تايي تقسيم شدند: گروه شاهد، گروههاي با 5 و 10 دقيقه غوطهوري در محلول گاز ازن در آب و گروههاي با 5 و 10 دقيقه اسپري محلول گاز ازن در آب. سپس قالبها با گچ نوع IV ريخته شدند. ابعاد و فاصله دايهاي گچي در هر گروه با دستگاه Coordinate measuring machine با دقت 1 ميكرون اندازهگيري شد. درصد تغييرات ابعادي قطر و ارتفاع دايها و فواصل بين آنها توسط آزمونهاي آماري ANOVA، One sample t و Paired-t مورد مقايسه قرار گرفتند (05/0 = ?).
يافتهها: آزمون ANOVA يك طرفه اختلاف معنيداري بين تغييرات ابعادي در گروههاي آزمون و گروه شاهد نشان نداد. قطر و ارتفاع دايها در تمام گروههاي مورد مطالعه نسبت به مدل اصلي كاهش يافت. آزمونOne sample t نشان داد كه به جز ارتفاع داي بدون آندركات در روش ضد عفوني اسپري به مدت 5 و 10 دقيقه (02/0 = p value و 01/0 = p value) و قطر داي با آندركات در روش ضد عفوني اسپري به مدت 10 دقيقه (02/0 = p value) در هيچ يك از ابعاد در مقايسه با مدل اصلي اختلاف معنيداري وجود نداشت. آزمون t-Paired در هيچ يك از گروههاي مورد بررسي تفاوت معنيداري بين ابعاد دايهاي با و بدون اندركات نشان نداد.
نتيجهگيري: دقت قالبهاي هيدروكلوييد برگشتناپذير تحت تاثير غوطهوري در محلول ازن در آب قرار نميگيرد. اسپري به مدت 5 و 10 دقيقه ميتواند دايهاي كوچكتري ايجاد كند.
كليد واژهها: كنترل عفونت، ضد عفوني، غوطهوري، مواد قالبگيري دندانپزشكي، مواد ضد عفوني كننده، ازن.
چكيده لاتين :
Abstract
Introduction: Disinfection of dental impressions is an essential step in dental infection control. The aim of this study was to evaluate dimensional accuracy of an irreversible hydrocolloid impression material after disinfection with either immersion in or being sprayed on by ozonated water.
Materials and Methods: In this in vitro study, 50 irreversible hydrocolloid impressions were made from an acrylic maxillary model including 4 Straumann abutment analogues and divided into 5 groups: control group, groups with 5 and 10 minutes of immersion in an ozone solution, and groups with 5 and 10 minutes of ozone solution sprayed on (n = 10). The impressions were then poured in type IV dental stone. Dimensions and distances of stone dies in each group were measured using Coordinate Measuring Machine with an accuracy of 1 micrometer. Percentages of dimensional changes in the diameter and height of the dies and the distances between them were statistically analyzed using ANOVA, one-sample t-test and paired t-test (? = 0.05).
Results: One-way ANOVA did not reveal any significant differences in dimensional changes between the test and control groups. Diameters and heights of the dies in all the groups decreased in comparison to the model. One-sample t-test showed that except for the height of the die without undercut in groups of 5- and 10-minute spray (p value = 0.01 and p value = 0.02) and the diameter of the die with undercut in the 10-minute spray group (p value = 0.02) there were no significant differences in any of the dimensions in comparison with the model. Paired t-test did not show any significant differences between dimensions of the dies with and without undercuts between the groups under study.
Conclusion: The accuracy of irreversible hydrocolloid impressions is not affected by immersion in ozonated water. Spraying for 5 and 10 minutes will lead to smaller dies.
Key words: Dental impression materials, Disinfectants, Disinfection, Immersion, Infection control, Ozone.
عنوان نشريه :
مجله دانشكده دندانپزشكي اصفهان
عنوان نشريه :
مجله دانشكده دندانپزشكي اصفهان
اطلاعات موجودي :
فصلنامه با شماره پیاپی 0 سال 1391
كلمات كليدي :
#تست#آزمون###امتحان