عنوان مقاله :
بررسي تاثير واش دوم در دو روش قالبگيري يك مرحلهاي و دو مرحلهاي بر تطابق لبهاي
عنوان فرعي :
Effect of the second wash in one- and two-step impression technique on marginal adaptation
پديد آورندگان :
نيلي ، منيره نويسنده Assistant Professor, Department of Prosthodontics, School of Dentistry, Khorasgan Branch, Islamic Azad University, Isfahan, Iran Nili, Monireh , قرباني، رضاعلي نويسنده DDS, Isfahan, Iran Ghorbani, Reza Ali
اطلاعات موجودي :
فصلنامه سال 1391 شماره 0
كليدواژه :
ماده قالب گيري , تطابق لبه اي , تكنيك قالب گيري , دندان
چكيده فارسي :
چكيده
مقدمه:موفقيت پروتز ثابت به ثبت و بازسازي دقيق دندان تراش خورده و خط خاتمه تراش وابسته است. لذا ارايه تكنيكي ساده كه بتوان بهترين قالب را از نظر ثبت جزييات بدست آورد لازم است. اين پژوهش به بررسي تاثير واش دوم بر تطابق لبه اي در دو روش قالب گيري يك مرحله اي و دو مرحله اي با نوعي سيليكون تراكمي پرداخت.
مواد و روش: در اين پژوهش تجربي از مدل آزمايشگاهي با دو داي فلزي (مشابه پرمولرو مولر دوم) و نوعي ماده قالب گيري سيليكون تراكمي استفاده شد. قالب گيري با چهار تكنيك يك مرحله اي، يك مرحله اي باواش دوم، دو مرحله اي با فضا و دو مرحله اي با واش دوم انجام شد. هر تكنيك 15 بار تكرارو60 قالب بدست آمد، كه با گچ استون تيپIV ريخته شد. بر روي داي ها الگوي مومي يك بريج سه واحدي فرم داده ومراحل كستينگ با آلياژ فلزي انجام شد. بااستفاده ازاستريوميكروسكوپ با بزرگنمايي 100× با ميكرومتر ديجيتال و با دقت ميكرون تطابق لبه اي در چهار ناحيه اندازه گيري و نتايج باآزمون آنوا و توكي آناليزگرديد. (?=0.05)
يافته ها: كمترين ميزان درز لبه اي مربوط به دندان قدامي در تكنيك دو مرحله اي (56/69 ميكرون) و بيشترين آن مربوط به دندان خلفي در تكنيك يك مرحله اي با واش دوم (59/85 ميكرون) بود. ميزان درز لبه اي در هر چهار تكنيك از نظر باليني قابل قبول بود. بين تكنيك هاي يك مرحله اي با دو مرحله اي (p value=1 )و يك مرحله اي باواش دوم با دو مرحله اي با واش دوم اختلاف معني داري وجود نداشت (6/0p value =).
نتيجه گيري: ميزان درز لبه اي براي هر چهار تكنيك قابل قبول بود. به نظر مي رسد مي توان با دادن واش دوم به واش اول قالبي دقيق از نظر ثبت جزييات و خط خاتمه تراش بدست آورد، كه نيازمند بررسي هاي بيشتر است.
كليد واژه ها: ماده قالب گيري، تكنيك قالب گيري، تطابق لبه اي، دندان.
چكيده لاتين :
Abstract
Introduction: The success of fixed prosthodontics requires a precise registration of the prepared teeth and finishing line, which necessitates finding to simple technique of impression taking so that an acceptable impression with record of details can be achieved. This research was performed to evaluate the effect of the second wash of Speedex impression material in one- and two-step impression technique on marginal adaptation of the crown.
Materials and methods: In this in vitro study a laboratory model with two metal dies (similar to the 2nd premolar the 2nd molar) and condensation silicone impression material (Speedex) were used. Impressions were made in four techniques (one-step, one-step with second wash, two-step with 2 mm of space, two-step with a second wash). Each technique was repeated 15 times and 60 impressions were obtained, which were poured with Type IV dental stone. On each die a wax pattern of a three-component bridge was framed and casting was carried out with a metal alloy. The marginal fitness of the frames was viewed and measured under a stereomicroscope at ×100 magnification with a digital micrometer in four areas. The results were analyzed by Tukey test and ANOVA.
Results: The least and greatest marginal gaps were observed in the anterior abutment with the two-step technique and the posterior abutment with one-step technique with a second wash (69.56 and 85.59 microns, respectively). The amounts of marginal gaps were clinically acceptable in all the four methods. There were no significant differences between the one-step and two-step techniques (p value = 1) and between one-step technique and two-step technique with a second wash (p value = 0.6).
Conclusion: For each four technique the amount of marginal gap was acceptable; therefore, a second wash can be added to the primary wash to achieve more precise impressions with registration of details and finishing line. However, further evaluations are necessary.
Key words: Impression material, Impression technique, Marginal adaptation, Tooth.
عنوان نشريه :
مجله دانشكده دندانپزشكي اصفهان
عنوان نشريه :
مجله دانشكده دندانپزشكي اصفهان
اطلاعات موجودي :
فصلنامه با شماره پیاپی 0 سال 1391
كلمات كليدي :
#تست#آزمون###امتحان