شماره ركورد :
618300
عنوان مقاله :
Effect of mechanical load cycling on class V glass- ionomer and composite restorations; a microleakage and scanning electron microscopic evaluation
پديد آورندگان :
Yassini، Esmaeil نويسنده Restorative Dentistry Department, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran , , Kermanshah، Hamid نويسنده , , Mirzaei، Mansoreh نويسنده Assistant Professor, Department of Operative Dentistry, School of Dentistry, Tehran University of Medical Sciences. Tehran, Iran , , Ranjbar Omidi ، Baharan نويسنده Assistant Professor, Department of Operative Dentistry, School of Dentistry, Qazvin University of Medical Sciences. Qazvin, Iran ,
اطلاعات موجودي :
فصلنامه سال 1391 شماره 83
رتبه نشريه :
علمي پژوهشي
تعداد صفحه :
10
از صفحه :
69
تا صفحه :
78
كليدواژه :
Composite resin , Glass ionomer cement , Microleakage
چكيده لاتين :
Abstract Background and Aim: Microleakage is an important problem with direct restorations and familiarity with its contributing factors is of utmost importance. The aim of this study was scanning electron microscopic evaluation of marginal integrity in three types of class V tooth-colored restorations and the effect of load cycling on their mi-croleakage. Materials and Methods: In this in vitro study, class V cavity preparations were made on the buccal and lingual surfaces of 30 bovine incisors (60 cavities). The specimens were divided into three groups (n=10 each or 20 cavities) and restored as follows: group 1:with Filtek Z350(nanocomposite), group 2: Fuji IX/G Coat Plus(CGIC) , and group 3: Fuji II LC(RMGI). All specimens were finished and polished immediately and were thermocycled (×2000,5-50 °C). In each group, half of the teeth were load cycled .Epoxy resin replicas of 12 specimens were evaluated under FE-SEM and interfacial gaps were measured. Finally the teeth were immersed in 0.5% basic fuchsine dye for 24 hours at room temperature, sectioned and observed under stereomicroscope. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests and a comparison between incisal and cervical microleakage was made with Wilcoxon test. Results: It was shown that the mechanical load cycling caused a statistically signifi-cant increase in cervical microleakage of Fuji IX and Fuji II LC and in incisal micro-leakage of Fuji II LC. Microleakage in Z350 with load-cycling and Fuji IX with and without load-cycling was significantly higher in cervical compared with incisal area. Both incisal and cervical microleakage were significantly different among these materials under load-cycling.) Fuji II LC < Fuji IX < Z350). Conclusion: It was concluded that the marginal sealing ability of Fuji IX under load-cycling was better than that of Fuji II LC. Z350 showed better marginal integrity while being load-cycled than both Fuji II LC and Fuji IX. Key Words: Microleakage - Glass ionomer cement - composite resin
سال انتشار :
1391
عنوان نشريه :
دندانپزشكي - جامعه اسلامي داندانپزشكان
عنوان نشريه :
دندانپزشكي - جامعه اسلامي داندانپزشكان
اطلاعات موجودي :
فصلنامه با شماره پیاپی 83 سال 1391
كلمات كليدي :
#تست#آزمون###امتحان
لينک به اين مدرک :
بازگشت