عنوان مقاله :
مقايسه تفاوت لندمارك هاي آناتوميك دو تكنيك راديوگرافي لترال سفالومتري ديجيتال و معمولي به روش ترسيم دستي در جمجمه هاي انساني
عنوان فرعي :
Determining the Degree of Identification Differences in Anatomical Landmarks by Digital Cephalometric Radiography and Conventional Radiographic Technique Using Manual Tracing of Human Skulls
پديد آورندگان :
اصلاني، فرزين نويسنده علوم پزشكي مازندران Aslani, farzin , عمراني، علي رضا نويسنده علوم پزشكي مازندران Omrani, Alireza , فيض بخش، مسعود نويسنده علوم پزشكي مازندران Feyzbakhsh, Masud , غفاري، روشنك نويسنده علوم پزشكي مازندران Ghafari, Roshanak , ثبوتي ، فرهاد نويسنده علوم پزشكي مازندران Sobuti, Farhad
اطلاعات موجودي :
ماهنامه سال 1393 شماره 114
كليدواژه :
digital radiography , راديوگرافي ديجيتال , سفالومتري , Anatomic landmarks , Cephalometry , لندماركهاي آناتوميك
چكيده فارسي :
Background and purpose: Digital radiography has led to many improvements in radiology.
Despite many advantages there are different ideas in determining anatomical landmarks which results in
some errors in cephalometric analyses. The aim of this study was to determine the degree of identification
differences of anatomical landmarks by conventional and digital lateral cephalometric techniques using
manual tracing of human skulls.
Material and Methods: This descriptive-analytical study was conducted in 17 cases of human
skulls in which metal radiopaque markers were attached to 9 landmarks as follows: N, S, ANS, PNS, A,
B, Pog, the most inferior point of lower mandibular border, and Go. Conventional and digital lateral
cephalograms were obtained from each skull with and without markers. The two cephalograms without
markers were traced for landmarks by three orthodontists. Any difference between these landmarks and
those of cephalograms with markers, were recorded and analyzed by student t-test.
Results: The level of differences in S point was not statistically significant along both x and y
coordinates. The measurement differences for the ANS and PNS points obtained by both radiographic
methods were significant along the x coordinate but not significant along the y coordinate. Also, the
measurement differences for the most inferior point of lower mandibular border, A, B, and Go points
along both x and y coordinates were observed to be statistically significant. The measurement difference
obtained for the Pog point was significant along the y coordinate and non-significant along the x
coordinate.
Conclusion:The difference in landmark identification between the two digital and conventional
lateral cephalometric techniques was statistically significant for some points on both dimensions,
however, the difference was not clinically significant.
چكيده لاتين :
Background and purpose: Digital radiography has led to many improvements in radiology. Despite many advantages there are different ideas in determining anatomical landmarks which results in some errors in cephalometric analyses. The aim of this study was to determine the degree of identification differences of anatomical landmarks by conventional and digital lateral cephalometric techniques using manual tracing of human skulls.
Material and Methods: This descriptive-analytical study was conducted in 17 cases of human skulls in which metal radiopaque markers were attached to 9 landmarks as follows: N, S, ANS, PNS, A, B, Pog, the most inferior point of lower mandibular border, and Go. Conventional and digital lateral cephalograms were obtained from each skull with and without markers. The two cephalograms without markers were traced for landmarks by three orthodontists. Any difference between these landmarks and those of cephalograms with markers, were recorded and analyzed by student t-test.
Results: The level of differences in S point was not statistically significant along both x and y coordinates. The measurement differences for the ANS and PNS points obtained by both radiographic methods were significant along the x coordinate but not significant along the y coordinate. Also, the measurement differences for the most inferior point of lower mandibular border, A, B, and Go points along both x and y coordinates were observed to be statistically significant. The measurement difference obtained for the Pog point was significant along the y coordinate and non-significant along the x coordinate.
Conclusion: The difference in landmark identification between the two digital and conventional lateral cephalometric techniques was statistically significant for some points on both dimensions, however, the difference was not clinically significant.
عنوان نشريه :
مجله دانشگاه علوم پزشكي مازندران
عنوان نشريه :
مجله دانشگاه علوم پزشكي مازندران
اطلاعات موجودي :
ماهنامه با شماره پیاپی 114 سال 1393
كلمات كليدي :
#تست#آزمون###امتحان