عنوان مقاله :
بررسي و مقايسه ريزنشت Nanofilled resin modified glass ionomer و Conventional glass ionomer در حفرات كلاس V با استفاده از دو نوع باندينگ Self etch adhesive و Self etch primer
عنوان فرعي :
Microleakage of class V cavities restored with nanofilled resin modified glass ionomer and conventional glass ionomer with self etch adhesive and self etch primer
پديد آورندگان :
میرزایی، منصوره نويسنده Associate Professor, Department of Operative, School of Dentistry, Tehran University of Medical Sciences Mirzaie, Mansore , یاسینی، اسماعیل نويسنده Professor, Department of Operative, School Of Dentistry, Tehran University of Medical Sciences Yasini, Esmaiel , عمرانی، لادن رنجبر نويسنده Assistant Professor, Department of Operative, School of Dentistry, Tehran University of Medical Sciences Omrani, Ladan Ranjbar , ركنی، مرتضی نويسنده Dentist Rokni, Morteza , درویشپور، حجت نويسنده Orthodontist Darvishpour, Hojat
اطلاعات موجودي :
فصلنامه سال 1394 شماره 0
كليدواژه :
Bonding , Leakage , باندينگ , ريزنشت , سمان گلاس آينومر , Glass ionomer cement
چكيده فارسي :
زمینه و هدف: ریزنشت به عنوان معیاری جهت ارزیابی موفقیت هر ماده ترمیمی مطرح بوده و دستیابی به سیل مناسب نیز در مارجینها مشكلات خاص خود را دارد، به ویژه در مارجینهای عاجی بسیار مشكلتر از مینای دندان میباشد. تحقیق حاضر با هدف مقایسه ریزنشت در مارجینهای مینایی و عاجی حفرههای كلاس V در دو نوع GI با استفاده از دو نوع باندینگ مختلف Self etch انجام شد.
روش بررسی: در سطوح باكال و لینگوال 40 دندان مولر، حفرههای كلاس V تهیه شد؛ طوری كه مارجین اكلوزالی حفرات در مینا و مارجین ژنژیوالی آنها
1 میلیمتر پایینتر از CEJ قرار بگیرد. دندانها به 4 گروه تقسیم شدند:گروه 1:Fuji IX ، G bond گروه 2: Fuji IX، SE bond گروه 3: GCP Glass fill،
G bond گروه 4: GCP glass fill، SE bond. نمونهها تحت چرخههای حرارتی قرار گرفتند؛ میزان ریز نشت اندازهگیری شد. جهت مقایسه ریزنشت از آزمون Kruskal-Wallis و برای مقایسه دو به دوی آنها از تصحیح Bonferroni استفاده شد (05/0P≤).
یافتهها: رتبههای ریزنشت در دیواره اكلوزال و ژنژیوال تمام گروههای آزمایشی برابر بوده است. در دیواره ژنژیوال، كمترین رتبههای ریزنشت مربوط به گروه Fuji IX+SE bond بوده و تفاوت آن با گروههای Fuji IX+G bond و Nanoglass+G bond معنیدار بود (05/0P≤). در دیوارهی اكلوزال؛ كمترین ریزنشت در گروه Fuji IX+SE bond دیده شد كه با هر 3 گروه دیگر تفاوت معنیداری داشته است (05/0P≤).
نتیجهگیری: استفاده از SE bond در مقایسه با G bond در كاهش میزان ریزنشت انواع سمانهای گلاسآینومر fuji IX) و (GCP glass Fill مؤثر بوده است.
چكيده لاتين :
Background and Aims: Microleakage is a criterion proposed for assessing the success of any restorative material. Complete seal is difficult especially for dentin margins compared to enamel margins. The aim of this study was to assess the microleakage at the enamel and dentin margins of class V cavities restored by two GIs and two self-etch adhesive systems.
Materials and Methods: This study was done on forty third molars. Class V cavities (3×2×2mm) were prepared on the buccal and lingual surfaces of teeth using high speed handpiece with 0.8 mm diamond fissure burr. The occlusal margins of the cavities in the enamel and gingival margins were placed 1 mm below the CEJ. The teeth were divided into 4 groups and the bondings were cured for 20 sec and the teeth were restored. The specimens were kept in distilled water at the temperature of 37°C for 24 hrs. The teeth were thermo cycled and cut in buccolingual direction using diamond disc under water. The dye penetration was evaluated using a stereomicroscope and the leakage was scored. The scores were compared using Kruskal-Wallis test while the paired comparisons were done using Bonferroni correction. P≤0.05 was regarded as significant results.
Results: Microleakage scores were similar at the occlusal and gingival walls of all test groups. At the gingival walls, the least microleakage scores were observed. “Fuji IX + SE bond” group showed significant differences with the “Fuji IX + G bond” and “Nanoglass + G bond” groups (P≤0.05). At the occlusal walls, the least scores were observed in the “Fuji IX+SE bond” specimens which were significantly different from the other groups (P≤0.05).
Conclusion: Self-Cure glass ionomers yielded less microleakage scores compared to the different types of light-cures due to the less polymerization shrinkage.
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
عنوان نشريه :
دندانپزشكي دانشگاه علوم پزشكي تهران
اطلاعات موجودي :
فصلنامه با شماره پیاپی 0 سال 1394
كلمات كليدي :
#تست#آزمون###امتحان